[ Identification | Description | Input parameters | Links ]
E_monitor ComponentA square single monitor that measures the energy of the incoming x-rays. Based on neutron component written by Kristian Nielsen and Kim Lefmann Example: E_monitor(xmin=-0.1, xmax=0.1, ymin=-0.1, ymax=0.1, Emin=1, Emax=50, nE=20, filename="Output.nrj")
| Name | Unit | Description | Default | |
| nE | 1 | Number of energy channels | 20 | |
| filename | 1 | Name of file in which to store the detector image | 0 | |
| xmin | m | Lower x bound of detector opening | -0.05 | |
| xmax | m | Upper x bound of detector opening | 0.05 | |
| ymin | m | Lower y bound of detector opening | -0.05 | |
| ymax | m | Upper y bound of detector opening | 0.05 | |
| xwidth | m | Width of detector. Overrides xmin,xmax. | 0 | |
| yheight | m | Height of detector. Overrides ymin,ymax. | 0 | |
| Emin | keV | Minimum energy to detect | ||
| Emax | keV | Maximum energy to detect | ||
| restore_xray | 1 | If set, the monitor does not influence the xray state | 0 | |
| nowritefile | 1 | If set, monitor will skip writing to disk | 0 |
| AT ( | , | , | ) RELATIVE | |||
|---|---|---|---|---|---|---|
| ROTATED ( | , | , | ) RELATIVE |